Technical white paper | HP MSA 1040/2040
25
Table 3. HP MSA 1040/2040 RAID levels (Continued)
RAID
level
M
inimum
disks
Allowable
disks
Description Strengths Weaknesses
6 4 16 Block-level data striping
with double distributed
parity
Best suited for large sequential
workloads; non-sequential read and
sequential read/write performance is
comparable to RAID 5; protects
against dual disk failure
Higher redundancy cost than
RAID 5 because the parity
overhead is twice that of
RAID 5; not well- suited for
transaction-oriented
network applications;
non-sequential write
performance is slower than
RAID 5
10
(1+0)
4 16
Stripes data
across
multiple
RAID 1 sub-
Disk
Groups
Highest performance and
data
protection (protects
against
multiple disk failures)
High redundancy cost
overhead:
because all
data is duplicated, twice
the
storage capacity is
required; requires
minimum of four disks
50
(5+0)
6 32 Stripes data
across
multiple
RAID
5 sub-Disk
Groups
Better random read and write
performance and data protection
than RAID 5; supports more disks
than RAID 5; protects against
multiple disk failures
Lower storage capacity
than RAID 5
Note
RAID types NRAID, RAID 0 and RAID 3 can only be created using the Command Line Interface (CLI) and are not available in the
SMU. When using Virtual Storage, only non-fault tolerant RAID types can be used in the Performance, Standard, and Archive
and Tiers. NRAID and RAID 0 are used with Read Cache as the data in the Read Cache SSDs is duplicated on either the
Standard or Archive Tier.
Volume mapping
For increased performance, access the volumes from the ports on the controller that owns the Disk Group, which would be
the preferred path. Accessing the volume on the non-preferred path results in a slight performance degradation.
Optimum performance with MPIO can be achieved with volumes mapped to multiple paths on both controllers. When the
appropriate MPIO drivers are installed on the host, only the preferred (optimized) paths will be used. The non-optimized
paths will be reserved for failover.
Best practices for SSDs
SSDs are supported in the MSA 2040 system only. The performance capabilities of SSDs are a great alternative to traditional
spinning hard disk drives (HDD) in highly random workloads. SSDs cost more in terms of dollars per GB throughput than
spinning hard drives; however, SSDs cost much less in terms of dollars per IOP. Keep this in mind when choosing the
numbers of SSDs per MSA 2040 array.